 Ultrasonic flow meters, including ultrasonic water meters, ultrasonic heat meters, and ultrasonic gas meters, are fully electronic flow meters made of industrial-grade electronic components using the principle of ultrasonic time difference. Using a pair of ultrasonic transducers to send and receive ultrasonic waves alternately (or simultaneously), the flow velocity of the fluid is indirectly measured by detecting the propagation time difference between the forward and reverse flow of the ultrasonic waves in the medium, and then the flow rate of the fluid is calculated by the flow velocity.

 

 Compared with traditional mechanical flow meters, ultrasonic flow meters have very important advantages: high precision, good reliability, wide range ratio, long life, no moving parts, can be installed at any angle, very flexible replacement, etc.

 

 However, for the application of the all-electronic smart flow meter, it is usually powered by a battery, and the battery is required to be used for at least 6 years. Therefore, this puts forward very strict requirements on the power consumption of the entire system, and has always restricted the development of ultrasonic flow meters. With the birth of ultra-low-power MCU and ultra-low-power ultrasonic dedicated measurement chip, the new ultra-low-power ultrasonic flow meter solution has successfully solved the problem of power consumption and met customer requirements. However, with the rise of the wireless centralized meter reading system, the power consumption problem is facing a severe test. The wireless module not only increases the power consumption, but also, due to the difference in the communication distance or the number of wall penetrations, the radio frequency transmission power is different, and the power consumption of each flow meter unit is also different, resulting in different battery life. The original method of uniform battery replacement is not very desirable.

lADPJwKtyEiQBr3NASrNApI_658_298

 We can detect the battery voltage. When the battery voltage is lower than a certain voltage value, an alarm will be sent to notify the system that the battery voltage is low and it is time to replace the battery. In this way, the battery can be replaced according to the actual service life of the battery, which can save costs on the one hand, and can prevent the battery voltage from being too low, which will lead to the failure of the flow meter and false reports and missed reports.

การตรวจจับแรงดันไฟฟ้า มีหลายวิธีที่จะบรรลุ วิธีหนึ่งคือการใช้การแปลง AD ของ CPU เองในการตรวจจับแรงดันไฟฟ้า แต่การใช้พลังงานมากเกินไป และไม่สามารถตรวจพบได้เป็นครั้งคราว และจำเป็นต้องตั้งค่าระยะเวลาการตรวจจับ หากตั้งระยะเวลาการตรวจจับนานขึ้น การสิ้นเปลืองพลังงานจะมีน้อย แต่การตรวจจับจะพลาดได้ง่าย หากตั้งระยะเวลาการตรวจจับสั้น การใช้พลังงานมากเกินไป ดังนั้นจึงไม่เหมาะ อีกวิธีหนึ่งคือการใช้ชิปตรวจจับแรงดันไฟแบบพิเศษสำหรับการตรวจจับแรงดันไฟ เมื่อแรงดันไฟฟ้าต่ำกว่าเกณฑ์แรงดันไฟฟ้าที่กำหนด ระบบจะแจ้งเตือน